APPLIED SURFACE TECHNOLOGIES INC. Company Profile | |||
---|---|---|---|
Company Name | Applied Surface Technologies Inc. | ||
Establishment Number | 234567112092 | ||
Website | - | ||
Phone | 613-969-5261 | ||
Established Year | - | ||
Province | Ontario | ||
Address | 379 Harrington Rd RR 2 FRANKFORD,Ontario K0K 2C0 |
||
Business Activity | Trading House / Wholesaler / Agent and Distributor | ||
Conatct Person | Martin Van Dyk (President) | ||
Phone Number | 613-969-5261 | ||
Fax Number | 613-969-5261 | ||
Country of Ownership | Canada | ||
Applied Surface Technologies Inc. Company Services | |
---|---|
Service | Service Description |
TEMP-COAT | I PRODUCTS TEMP-COAT® 101 Insul-All II APPROVALS & ACCEPTANCE GSA/NSN #8030 01 387 1027 Lloyd's Register of Shipping #SAS FOI0506 Approved: U.S. Coast Guard, MLCA Std 6300N P .35 Accepted for Certification by: USDA Accepted by: FDA Approved by: Dept. of Energy Accepted by: Navy Safety & Survivability S.I.C. Code: 5033 All Ingredients TSCA Listed III DESCRIPTION TEMP-COAT®101 is a general purpose insulation which comes in liquid form. It is widely used as a rooftop insulation, but performs extremely well on piping, air and heat duct work, exposed water pipes, oxygen lines, water tanks, steam lines and has many other uses. TEMP-COAT®101 provides an inexpensive alternative to the high cost of industrial insulations. Because it physically adheres to the surface that it is insulating, it significantly reduces corrosion and rust formations found under conventional insulations. Insul-All is a reformulation of TEMP-COAT®"101" pointed to the homeowner and do-it yourselfer. Polymers are added increasing the products ease of application. Insul-All contains less than .001% ethylene glycol. May be applied to surfaces up to 225 F. 15 mil thickness provides an equivalence of R-18. Make Up: TEMP-COAT®101 and Insul-AII are a complete mixture of various silicas and ceramic beads immersed in a high quality latex base with acrylic binders. This combination of materials makes the product extremely light weight and pliable, therefore, it expands and contracts with the surface to which it is applied. The resiliency of TEMP-COAT®101 and Insul-AII allow it to double as a leak stop even though it is not sold or warranted for that purpose. Other Properties: TEMP-COAT®101 works well on boat and barge decks and other surfaces as a method of controlling the surface temperature. TEMP-COAT®101 and lnsul-All can be tinted virtually any medium to pastel color. The tinting does have some affect on the radiant effectiveness of the product. Product Qualities: TEMP- COAT® 101 works well on both convective and conductive heat and cold. When used in ways, which does not require solar reflective qualities, its effectiveness has different values. Unlike conventional insulation such as fiberglass batting, blankets, foam, fiber insulations, or calcium silicate type pre-formed insulation for piping or enclosures having temperatures below 400O F*, TEMP- COAT® 101 is impervious to water and is not affected by salt water. As this product is a liquid, it forms a continuous covering and not sectioned as installed conventional products. It also forms an excellent weatherproof coating over the other forms of insulation. ACCORDING TO RADIANT HEAT TEST RESULTS IN A ROOF TOP APPLICATION. TEMP-COAT® 101 WHEN APPLIED TO A THICKNESS OF 15 MILS. PERFORMS AS WELL AS A 4" THICKNESS OF FOAM WITH AN R- 20 RATING. * Test results for Roof Top Applications Product Limits: TEMP-COAT® 101 and Insul-All aid in sealing leaks but is not sold as a leak-stop material. Product must he applied over a clean, dry, grease and dirt free substrate. TEMP-COAT® 101s operating temperatures can be from 0oF to 400°F*. It can be applied to temperatures ranging from 45oF to 350°F**. On extremely warm to hot surfaces, beginning coats must be thin to avoid blistering. ** In some instances for temperatures 350oF to 400°F a mesh/membrane must be used and the High Heat Application Instructions must be followed. IV. APPLICATION Apply TEMP-COAT® 101 /Insul-All on any clean, dry substrate which is free from oil, grease, wax or dirt. A sufficient amount of Primer on all surfaces prone to rust and to prevent bleed through is recommended. Apply by use of brush, roller, airless spray or air assisted QuikGun. Strain product before spraying. Spray equipment requirement: 5.4 GPM, 28: 1 ratio airless sprayer or the air assisted "QuikGun". Allow product to dry between coats. This is a one-coat system with curing time of 24 hours under normal conditions. Approximate Coverage: Spray: 60 SF per gallon at 15 mil thickness on a flat surface. On Pipe: 20 mil thickness 4" O.D. LF per gallon = 56 8" O.D. LF per gallon = 24 12" O.D. LF per gallon = 15 |
TEMP-COAT® | TEMP-COAT® is a liquid latex barrier form of insulation that has many uses for Industry, Commerce and the Home owner. It separates the heat from the cold. |
Applied Surface Technologies Inc. Company Business Activity | |
---|---|
Activity ID | Activity |
416390 | Other Specialty-Line Building Supplies Wholesaler-Distributors |
Problem with this data ?
Click here